<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-28 17-49-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 60 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 70 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19078 0,8858
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,4 dBr 3,79 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 17:49, 28.10.2025
RT
"YleX Ilta: Henkka Remes "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,8858 Acquired: 2025/10/28 17.48.31 Total samples: 19078 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,1 dBr MIN: 2,4 dBr AVE: 3,79 dBr % above 12,2 dBr: 0,0 Last value: 4,9 dBr (2025/10/28 17.48.31) 17.34 17.36 17.38 17.40 17.42 17.44 17.46 17.48 0 2 4 6 Pm [dBr]